IT SERIES
KWIK-LATCH® CURRENT TRANSFORMERS
The IT KWIK-LATCH® series are wideband current transformers that are used to inductively couple current on cables or conductors to be tested. The latch type design allow fast and simple attachment without having to pass cables or conductors through the aperture. Other aperture sizes and output connectors are available to meet the unique application.
Pertinent Equations
Insertion Loss = db = 20 Log10 I induced or I induced = I drive x 10-db
I drive 20

Specifications
MODEL |
||||
IT-050-1 |
IT-075-1 |
IT-125-1 |
IT-125-2 |
|
| Electrical | ||||
| Frequency Range | 100KHz -100MHz |
100KHz -100MHz |
100KHz -100MHz |
50KHz - 700MHz |
| Insertion Loss 1 (db) | 20 + 3 |
20 + 3 |
20 + 3 |
10 + 3 |
| Turns Ratio | 10 |
10 |
10 |
1 |
| Typical Saturation Level | ||||
| Pulse (amp =m sec) | ~20* n . RL |
~20* n . RL |
~20* n . RL |
~20* n . RL |
| CW(amps peak)MHz | ~20*p f n . RL |
~20*p f n . RL |
~20*p f n . RL |
~20*p f n . RL |
| Physical | ||||
| Connector | Type N |
Type N |
Type N |
Type N |
| Dimensions (in.) A | .50 |
.75 |
1.25 |
1.25 |
D |
2.75 |
3.00 |
3.25 |
3.25 |
T |
1.37 |
1.37 |
1.37 |
1.37 |
*R Function of turns ratio and core material
1:nominal Insertion Loss (a calibration curve is supplied with each unit)

![]()