MODEL I-125
KWIK-LATCH® CURRENT PROBE
The PRODYN KWIK-LATCH® Current Probes are wide band devices designed to mea-sure current on cable bundles and other RF sources without having to disconnect the conductor. The probes have a mid-sized aperture of 1.25 inches and have a hinged two piece design that is durable and easy to use. The I-125 Current Probes have a 50 W output load impedance and come with a type 'N' connector standard. (Other connector types are available at a slight additional charge.)

MODEL |
Zt W |
USABLE FREQUENCY RANGE |
3 db POINTS |
| I-125-1A | 5 |
10 KHz to 100 MHz |
110 KHz to 90 MHz |
| I-125-1D | 5 |
1 KHz to 110 MHz |
25 KHz to 80 MHz |
I-125-1E |
5 | 850 Hz to 120 MHz | 5 KHz to 70 MHz |
| I-125-1 HF | 5 |
50 KHz to > 1 GHz |
120 KHz to >600 MHz |
| I-125-2A | 1 |
10 KHz to 150 MHz |
30 KHz to 80 MHz |
| I-125-2C | 1 |
300 Hz to 25 MHz |
600 Hz to 10 MHz |
| I-125-2 HF | 1 |
50 KHz to > 1 GHz |
80 KHz to >500 MHz |
| I-125-7A | 1 |
400 Hz to 100 MHz |
540 Hz to 30 MHz |
| I-125-6A | .5 |
20 Hz to 30 MHz |
60 Hz to 10 MHz |
| I-125-4A | .1 |
1 KHz to 150 MHz |
4 KHz to 110 MHz |
| I-125-3A | .03 |
1 KHz to 250 MHz |
10 KHz to 180 MHz |
| I-125-9A | .005 |
1 KHz to 270 MHz |
10 KHz to 200 MHz |
Additional electrical data available upon request.
PRODYN manufactures current probes with larger or smaller apertures and different frequency
ranges. Please ask for additional information.
![]()