IP-10 and IP-50
The PRODYN IP-10, IP-50 are small wideband current probes
that were developed to test current on small diameter conductors
that can be inserted through the aperture.
| |
IP-10
|
IP-50
|
|
Bandwidth (3 db points)
|
20 KHz to 400 MHz
|
300 KHz to 400 MHz
|
|
Transfer Impedance
|
1 W
|
5 W
|
|
Bandpass Flatness (+ .5 db)
|
100 KHz to 100 MHz
|
1 KHz to 100 MHz
|
|
Current Handling Capability (CW)
|
1 amp (RMS)
|
1 amp (RMS)
|
|
Maximum Pulse Input
|
1 amp ms
|
1 amp msec
|
|
Connector
|
SMC Jack
|
SMC Jack
|
NOTE: Other connectors and transfer impedances are available. Please consult
PRODYN for details.