IT SERIES
KWIK-LATCH® CURRENT TRANSFORMERS
The IT KWIK-LATCH® series are wideband current transformers that are used
to inductively couple current on cables or conductors to be tested. The latch type
design allow fast and simple attachment without having to pass cables or conductors
through the aperture. Other aperture sizes and output connectors are available to
meet the unique application.
Pertinent Equations
Insertion Loss = db = 20 Log10 Iinduced or I induced = I drive x 10-db
I drive 20

Specifications
| |
|
MODEL
|
|
|
| |
IT-050-1
|
IT-075-1
|
IT-125-1
|
IT-125-2
|
| Electrical |
|
|
|
|
| Frequency Range |
100KHz -100MHz
|
100KHz -100MHz
|
100KHz -100MHz
|
50KHz - 700MHz
|
| Insertion Loss 1 (db) |
20 + 3
|
20 + 3
|
20 + 3
|
10 + 3
|
| Turns Ratio |
10
|
10
|
10
|
1
|
| Typical Saturation Level |
|
|
|
|
| Pulse (amp =m sec) |
~20*
n . RL
|
~20*
n . RL
|
~20*
n . RL
|
~20*
n . RL
|
| CW(amps peak)MHz |
~20*p f
n . RL
|
~20*p f
n . RL
|
~20*p f
n . RL
|
~20*p f
n . RL
|
| |
|
|
|
|
| Physical |
|
|
|
|
| Connector |
Type N
|
Type N
|
Type N
|
Type N
|
| Dimensions (in.) A |
.50
|
.75
|
1.25
|
1.25
|
D
|
2.75
|
3.00
|
3.25
|
3.25
|
T
|
1.37
|
1.37
|
1.37
|
1.37
|
*R Function of turns ratio and core material